Autor Borba Neves, Eduardo
|
|
Documentos disponibles escritos por este autor (4)
Hacer una sugerencia Refinar búsquedaRESPIRATORY FUNCTION IN CHILDREN WITH CEREBRAL PALSY / Neves, Eduardo Borba en Archivos de medicina, Vol. 23 Num. 1 Año. 2023 ([04/09/2023])
![]()
[artÃculo]
TÃtulo : RESPIRATORY FUNCTION IN CHILDREN WITH CEREBRAL PALSY Tipo de documento: documento electrónico Autores: Neves, Eduardo Borba, Autor ; Borba Neves, Eduardo, Autor ; Almeida, Karielly Cássia de, Autor ; Rasera, Carmen Caroline, Autor ; Ripka, Wagner Luis, Autor ; Mélo, Tainá Ribas, Autor Editorial: Manizales [Colombia] : Universidad de Manizales* Fecha de publicación: 2023 Resumen: Purpose: to characterize the pulmonary function of children with cerebral palsy (CP) and to compare it with children with typical development (TD). Methods: the study was with 20 children TD and 21 CP, both sexes aged between 6-12 years (9.41 ± 1.47), with cognitive ability to perform the spirometry test. Wilcoxon / Mann Whitney test hypothesis compare the values obtained in both groups and intragroup in relation to gender and in the functional classifications of CP. Results: TD group showed a significant difference and higher spirometry values in males, whereas for children with CP there was no difference in relation to sex. In addition, the TD group demonstrated better values of forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEF) than the CP group. There were significant differences and better spirometric values for children with CP less compromised in the comparisons between the functional, topographic levels, and functional gait pattern. Conclusion: there is a tendency towards obstructive and restrictive breathing patterns in the children with CP, observable mainly by the decrease in FVC, FEV1, and PEF compared DT. CP children with worse functionality have greater respiratory impairments.
Tipo de medio : Computadora En lÃnea: https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view [...] Link: https://biblioteca.umanizales.edu.co/ils/opac_css/index.php?lvl=notice_display&i
in Archivos de medicina > Vol. 23 Num. 1 Año. 2023 [04/09/2023][artÃculo] RESPIRATORY FUNCTION IN CHILDREN WITH CEREBRAL PALSY [documento electrónico] / Neves, Eduardo Borba, Autor ; Borba Neves, Eduardo, Autor ; Almeida, Karielly Cássia de, Autor ; Rasera, Carmen Caroline, Autor ; Ripka, Wagner Luis, Autor ; Mélo, Tainá Ribas, Autor . - Manizales [Colombia] : Universidad de Manizales*, 2023.
in Archivos de medicina > Vol. 23 Num. 1 Año. 2023 [04/09/2023]
Resumen: Purpose: to characterize the pulmonary function of children with cerebral palsy (CP) and to compare it with children with typical development (TD). Methods: the study was with 20 children TD and 21 CP, both sexes aged between 6-12 years (9.41 ± 1.47), with cognitive ability to perform the spirometry test. Wilcoxon / Mann Whitney test hypothesis compare the values obtained in both groups and intragroup in relation to gender and in the functional classifications of CP. Results: TD group showed a significant difference and higher spirometry values in males, whereas for children with CP there was no difference in relation to sex. In addition, the TD group demonstrated better values of forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEF) than the CP group. There were significant differences and better spirometric values for children with CP less compromised in the comparisons between the functional, topographic levels, and functional gait pattern. Conclusion: there is a tendency towards obstructive and restrictive breathing patterns in the children with CP, observable mainly by the decrease in FVC, FEV1, and PEF compared DT. CP children with worse functionality have greater respiratory impairments.
Tipo de medio : Computadora En lÃnea: https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view [...] Link: https://biblioteca.umanizales.edu.co/ils/opac_css/index.php?lvl=notice_display&i Tecnologias para o Diagnóstico da Radiodermite: uma Revisão Sistemática / Borba Neves, Eduardo en Archivos de medicina, Vol. 20 Num. 2 Año. 2020 ([03/07/2020])
![]()
[artÃculo]
TÃtulo : Tecnologias para o Diagnóstico da Radiodermite: uma Revisão Sistemática Tipo de documento: documento electrónico Autores: Borba Neves, Eduardo, Autor ; Iede Shiguihara, Dryelle Soster, Autor ; Brandao Oselame, Gleidson, Autor Editorial: Manizales [Colombia] : Universidad de Manizales* Fecha de publicación: 2020 ArtÃculo en la página: páginas:331-343 Resumen: Objetivo: a radiodermite ou radiodermatite é uma reação celular inflamatória desencadeada pela radioterapia, que é uma das alternativas para tratamento de vários tipos de cânceres. O objetivo deste trabalho foi analisar os principais métodos de diagnóstico de radiodermite com uso de ferramentas tecnológicas, quanto a equipamentos utilizados, forma de análise clÃnica, parâmetros desenvolvidos e produto final. Materiais e métodos: optou-se pela revisão sistemática de caráter exploratório e abordagem qualitativa. A busca por estudos em periódicos internacionais foi realizada no mês de julho de 2019, nas bases de dados MEDLINE e SCOPUS. Foram utilizados os descritores “radiodermatitis†e “acute radiation dermatitisâ€, para a busca. Os critérios de inclusão foram: artigo, escrita em inglês, publicação nos últimos dez anos (01/2009 a 07/2019), e conteúdo relacionado ao diagnóstico de radiodermite causada por radioterapia de aplicação exclusiva. Resultados: esta revisão encontrou estudos sobre as seguintes ferramentas tecnológicas: avaliação citológica, avaliação de fluxo sanguÃneo, machine learning, escala fotográfica, imagem térmica, dose de irradiação e espectrofotometria. O uso de imagens fotográficas e térmicas tem se consolidado como ferramenta de diagnóstico importante na área médica. Essas ferramentas tecnológicas têm se mostrado aplicáveis ao diagnóstico da radiodermite, com seu efeito potencializado por processamento digital de imagens e algoritmos de inteligência artificial. Conclusões: a análise aqui descrita demonstra a necessidade de desenvolvimento tecnológico para delineamento e padronização do processo de diagnóstico da radiodermite, o que permitiria tratamento precoce e manutenção do engajamento do indivÃduo na terapia antineoplásica.
Â
Tipo de medio : Computadora En lÃnea: https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view [...] Link: https://biblioteca.umanizales.edu.co/ils/opac_css/index.php?lvl=notice_display&i
in Archivos de medicina > Vol. 20 Num. 2 Año. 2020 [03/07/2020] . - páginas:331-343[artÃculo] Tecnologias para o Diagnóstico da Radiodermite: uma Revisão Sistemática [documento electrónico] / Borba Neves, Eduardo, Autor ; Iede Shiguihara, Dryelle Soster, Autor ; Brandao Oselame, Gleidson, Autor . - Manizales [Colombia] : Universidad de Manizales*, 2020 . - páginas:331-343.
in Archivos de medicina > Vol. 20 Num. 2 Año. 2020 [03/07/2020] . - páginas:331-343
Resumen: Objetivo: a radiodermite ou radiodermatite é uma reação celular inflamatória desencadeada pela radioterapia, que é uma das alternativas para tratamento de vários tipos de cânceres. O objetivo deste trabalho foi analisar os principais métodos de diagnóstico de radiodermite com uso de ferramentas tecnológicas, quanto a equipamentos utilizados, forma de análise clÃnica, parâmetros desenvolvidos e produto final. Materiais e métodos: optou-se pela revisão sistemática de caráter exploratório e abordagem qualitativa. A busca por estudos em periódicos internacionais foi realizada no mês de julho de 2019, nas bases de dados MEDLINE e SCOPUS. Foram utilizados os descritores “radiodermatitis†e “acute radiation dermatitisâ€, para a busca. Os critérios de inclusão foram: artigo, escrita em inglês, publicação nos últimos dez anos (01/2009 a 07/2019), e conteúdo relacionado ao diagnóstico de radiodermite causada por radioterapia de aplicação exclusiva. Resultados: esta revisão encontrou estudos sobre as seguintes ferramentas tecnológicas: avaliação citológica, avaliação de fluxo sanguÃneo, machine learning, escala fotográfica, imagem térmica, dose de irradiação e espectrofotometria. O uso de imagens fotográficas e térmicas tem se consolidado como ferramenta de diagnóstico importante na área médica. Essas ferramentas tecnológicas têm se mostrado aplicáveis ao diagnóstico da radiodermite, com seu efeito potencializado por processamento digital de imagens e algoritmos de inteligência artificial. Conclusões: a análise aqui descrita demonstra a necessidade de desenvolvimento tecnológico para delineamento e padronização do processo de diagnóstico da radiodermite, o que permitiria tratamento precoce e manutenção do engajamento do indivÃduo na terapia antineoplásica.
Â
Tipo de medio : Computadora En lÃnea: https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view [...] Link: https://biblioteca.umanizales.edu.co/ils/opac_css/index.php?lvl=notice_display&i The reproducibility of the 1hz gps in the aciclic displacement with intermittent intensity / Borba Neves, Eduardo en Archivos de medicina, Vol. 21 Num. 1 Año. 2021 ([03/01/2021])
![]()
[artÃculo]
TÃtulo : The reproducibility of the 1hz gps in the aciclic displacement with intermittent intensity Tipo de documento: documento electrónico Autores: Borba Neves, Eduardo, Autor ; de Lima e Silva, Leandro, Autor ; Valente dos Santos, Luciano Alonso, Autor ; Baptista Da Silva, Jurandir, Autor ; Gomes de Souza Vale, Rodrigo, Autor ; Moreira Nunes, Rodolfo de Alkmim, Autor Editorial: Manizales [Colombia] : Universidad de Manizales* Fecha de publicación: 2020 ArtÃculo en la página: páginas:85-91 Resumen: Objective: the aim of this study was to verify the reproducibility index of the frequency meter with GPS technology with recording speed of 1Hz in acyclic displacement and intermittent intensity, performed by soccer referees. Materials and methods: it was characterized by a field study with a quantitative trait involving 14 men, aged 20.42 ±
2.78 years, from a barracks in the city of Rio de Janeiro. Polar heart rate monitor with 1Hz GPS model V800 was used. The protocol used was adapted from the FIFA test protocol for soccer referees, so that 10 “shots†of 75m in 15s were accomplished by 25m in 20 of recovery. Testing and retest were applied with 7 days interval and identical protocols: heating, ambiance (4 “shots†following the model of the protocol above)
and then the test. Since the circuit covered in the test protocol was 1000 m. Results: a mean of 1002.5 ± 17.12 m was obtained in the test and in the test 1010.83 ± 32.88 m, the coefficients of variation were respectively 1% and 3%. The difference was not
significant between the test and the retest (P-alue> 0.05), and the intraclass correlation coefficient indicated a moderate association between the measures. Conclusion: therefore, it is suggested that it is acceptable to use a frequency gauge with a recording speed of 1Hz to monitor displacements of soccer referees in acyclic displacement and
intermittent intensity.Tipo de medio : Computadora En lÃnea: https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view [...] Link: https://biblioteca.umanizales.edu.co/ils/opac_css/index.php?lvl=notice_display&i
in Archivos de medicina > Vol. 21 Num. 1 Año. 2021 [03/01/2021] . - páginas:85-91[artÃculo] The reproducibility of the 1hz gps in the aciclic displacement with intermittent intensity [documento electrónico] / Borba Neves, Eduardo, Autor ; de Lima e Silva, Leandro, Autor ; Valente dos Santos, Luciano Alonso, Autor ; Baptista Da Silva, Jurandir, Autor ; Gomes de Souza Vale, Rodrigo, Autor ; Moreira Nunes, Rodolfo de Alkmim, Autor . - Manizales [Colombia] : Universidad de Manizales*, 2020 . - páginas:85-91.
in Archivos de medicina > Vol. 21 Num. 1 Año. 2021 [03/01/2021] . - páginas:85-91
Resumen: Objective: the aim of this study was to verify the reproducibility index of the frequency meter with GPS technology with recording speed of 1Hz in acyclic displacement and intermittent intensity, performed by soccer referees. Materials and methods: it was characterized by a field study with a quantitative trait involving 14 men, aged 20.42 ±
2.78 years, from a barracks in the city of Rio de Janeiro. Polar heart rate monitor with 1Hz GPS model V800 was used. The protocol used was adapted from the FIFA test protocol for soccer referees, so that 10 “shots†of 75m in 15s were accomplished by 25m in 20 of recovery. Testing and retest were applied with 7 days interval and identical protocols: heating, ambiance (4 “shots†following the model of the protocol above)
and then the test. Since the circuit covered in the test protocol was 1000 m. Results: a mean of 1002.5 ± 17.12 m was obtained in the test and in the test 1010.83 ± 32.88 m, the coefficients of variation were respectively 1% and 3%. The difference was not
significant between the test and the retest (P-alue> 0.05), and the intraclass correlation coefficient indicated a moderate association between the measures. Conclusion: therefore, it is suggested that it is acceptable to use a frequency gauge with a recording speed of 1Hz to monitor displacements of soccer referees in acyclic displacement and
intermittent intensity.Tipo de medio : Computadora En lÃnea: https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view [...] Link: https://biblioteca.umanizales.edu.co/ils/opac_css/index.php?lvl=notice_display&i VO2 Estimation Equation Accuracy to Young Adults / Fortes GarcÃa, Rafael Chieza en Archivos de medicina, Vol. 20 Num. 1 Año. 2020 ([18/01/2020])
![]()
[artÃculo]
TÃtulo : VO2 Estimation Equation Accuracy to Young Adults Tipo de documento: documento electrónico Autores: Fortes GarcÃa, Rafael Chieza, Autor ; Melo de Oliveira, Rafael, Autor ; MartÃnez, Eduardo Camilo, Autor ; Borba Neves, Eduardo, Autor Editorial: Manizales [Colombia] : Universidad de Manizales* Fecha de publicación: 2019 ArtÃculo en la página: páginas:33-39 Resumen: A
Objetivos: analizar la concordancia de los valores de VO2max estimados por las ecuaciones del Colegio Americano de Medicina del Deporte y de Foster con el análisis de gases de medida directa en varones brasileños jóvenes. el consumo máximo de oxigeno, como un indicador de salud y predictor de mortalidad, se puede evaluar de diferentes maneras. El estándar de oro comprende la medición directa de los gases exhalados, lo que implica un alto costo. Una forma más conveniente puede ser las ecuaciones de estimación. Materiales y métodos: este estudio evaluó el VO2máx de 41 hombres brasileños jóvenes (21,4 ± 2,2 años) mediante una prueba de ejercicio cardiopulmonar en un ergómetro en cinta ergométrica con un protocolo de rampa. El análisis de Bland y Altman se realizó para verificar la concordancia entre V̇O2max medido y valores estimados por las ecuaciones del ACSM y de Foster. Resultados: el VO2max medido fue de 52,3 ± 4,9 ml.kg-1.min-1. La diferencia entre el V̇O2max medido y el VO2max estimado por la ecuación ACSM (9,40 ± 3,67) fue aproximadamente 7.5 veces mayor que la diferencia entre el VO2max medido y el VO2max estimado por la ecuación de Foster (1,25 ± 3,46). Los gráficos de Bland Altman muestran que solo la ecuación de ACSM tenÃa diferencias estadÃsticas del valor medido. Conclusiones: la ecuación ACSM no fue adecuada durante la prueba de ejercicio en cinta de correr en adultos jóvenes en un protocolo de rampa y la ecuación de Foster parece ser un estimador más preciso de VO2max para esta población, además mostró un sesgo a lo largo de la capacidad aeróbica, con tendencia a sobreestimar y subestimar VO2 máx. de personas menos y más en preparadas, respectivamente.
as, respectivamente.
Tipo de medio : Computadora En lÃnea: https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view [...] Link: https://biblioteca.umanizales.edu.co/ils/opac_css/index.php?lvl=notice_display&i
in Archivos de medicina > Vol. 20 Num. 1 Año. 2020 [18/01/2020] . - páginas:33-39[artÃculo] VO2 Estimation Equation Accuracy to Young Adults [documento electrónico] / Fortes GarcÃa, Rafael Chieza, Autor ; Melo de Oliveira, Rafael, Autor ; MartÃnez, Eduardo Camilo, Autor ; Borba Neves, Eduardo, Autor . - Manizales [Colombia] : Universidad de Manizales*, 2019 . - páginas:33-39.
in Archivos de medicina > Vol. 20 Num. 1 Año. 2020 [18/01/2020] . - páginas:33-39
Resumen: A
Objetivos: analizar la concordancia de los valores de VO2max estimados por las ecuaciones del Colegio Americano de Medicina del Deporte y de Foster con el análisis de gases de medida directa en varones brasileños jóvenes. el consumo máximo de oxigeno, como un indicador de salud y predictor de mortalidad, se puede evaluar de diferentes maneras. El estándar de oro comprende la medición directa de los gases exhalados, lo que implica un alto costo. Una forma más conveniente puede ser las ecuaciones de estimación. Materiales y métodos: este estudio evaluó el VO2máx de 41 hombres brasileños jóvenes (21,4 ± 2,2 años) mediante una prueba de ejercicio cardiopulmonar en un ergómetro en cinta ergométrica con un protocolo de rampa. El análisis de Bland y Altman se realizó para verificar la concordancia entre V̇O2max medido y valores estimados por las ecuaciones del ACSM y de Foster. Resultados: el VO2max medido fue de 52,3 ± 4,9 ml.kg-1.min-1. La diferencia entre el V̇O2max medido y el VO2max estimado por la ecuación ACSM (9,40 ± 3,67) fue aproximadamente 7.5 veces mayor que la diferencia entre el VO2max medido y el VO2max estimado por la ecuación de Foster (1,25 ± 3,46). Los gráficos de Bland Altman muestran que solo la ecuación de ACSM tenÃa diferencias estadÃsticas del valor medido. Conclusiones: la ecuación ACSM no fue adecuada durante la prueba de ejercicio en cinta de correr en adultos jóvenes en un protocolo de rampa y la ecuación de Foster parece ser un estimador más preciso de VO2max para esta población, además mostró un sesgo a lo largo de la capacidad aeróbica, con tendencia a sobreestimar y subestimar VO2 máx. de personas menos y más en preparadas, respectivamente.
as, respectivamente.
Tipo de medio : Computadora En lÃnea: https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view [...] Link: https://biblioteca.umanizales.edu.co/ils/opac_css/index.php?lvl=notice_display&i